Skip to main content
Nach oben
Card payment
International Shipping
Customer Service

2-fibre AXAI, 9/OS2, E2000/PC-E2000/PC

Von: exkl. MwSt.
Zeige die Ausführungen

Pre-terminated break-out fiber optic cable with E2000/PC-E2000/PC connectors. The AXAI single mode cable is terminated in both ends when delivered, each fibre in the cable is distributed to the ends via a fan-out. Combined in- and outdoor use.

Ausführung Bestellnummer Length Lieferzeit Preis
Ausführung: 2-fibre AXAI, 9/OS2, E2000/PC-E2000/PC, 10 m Nummer: F-B692110-F-010 Length 10 m
Lieferzeit:
Preis:
Ausführung: 2-fibre AXAI, 9/OS2, E2000/PC-E2000/PC, 20 m Nummer: F-B692110-F-020 Length 20 m
Lieferzeit:
Preis:
Ausführung: 2-fibre AXAI, 9/OS2, E2000/PC-E2000/PC, 30 m Nummer: F-B692110-F-030 Length 30 m
Lieferzeit:
Preis:
Ausführung: 2-fibre AXAI, 9/OS2, E2000/PC-E2000/PC, 50 m Nummer: F-B692110-F-050 Length 50 m
Lieferzeit:
Preis:
  • connector: E2000/PC according to IEC 61 754-15
  • Fibre type: Single mode according to ITU-T G657A1, EN 50173-1 OS2
  • Quality: IEC 61755-1 class C1
  • Cable type: AXAI, tight buffer, fire retardant and halogen free, yellow
  • Each fibre in the cable is protected with a 3mm furcation tube in both ends
  • Each fibre in the cable is distributed to the ends with a fan-out
  • The fibres has a decreasing length (see datasheet)
  • As an option the cable end can be delivered with protection and a pulling hose
  • For indoor use
  • Other lengths can quickly be delivered from our production facilities in Drammen. Please contact us regarding this.

    Specifications

    Cable type:  
    Tight buffer, AXAI, yellow               Flame retardant, Zero halogen  


    Diameter cable:  
    4.5/5/6/6.5/8 mm                           2/4/8/12/24-fibre AXAI  

    Tension strength cable:  
    325/440/680/900/1400 N             2/4/8/12/24-fibre AXAI  

    Dimensions manifold (fan-out):
    Ø 14 mm x 36 mm               2-fibre  
    Ø 20 mm x 75 mm              4-fibre  
    Ø 17 mm x 105 mm              8-fibre  
    Ø 35 mm x 165 mm             12/24-fibre

    Diameter protection w/cable grip:
    32 mm                                   2/4/8-fibre  
    52 mm                                   12/24-fibre  

    Diameter detachable protection:
    49 mm (accessory 990443 - tube: Ø28 mm)                 2/4/8-fibre  
    63 mm (accessory 990145 - tube: Ø42 mm)                  12/24-fibre  

    Fibre type:  
    ITU-T G.657.A1 (compatible with G.652.D)       AXAI  
    OS-2                                                                         EN 50173-1

    Insertion loss connectors:  
    < 0.5 dB @ 1310/1550 nm                                      < 0.15 dB typical

    Return loss connectors:  
    < -45 dB @ 1310/1550 nm for PC                         < -50 dB typical  
    < -60 dB @1310/1550 nm for APC                       < -65 dB typical

    Classification, connectors:
    Class C2 (PC), class C1 (APC)                              IEC 61755-1

    Operating temperature:  
    -40°C to 60°C  


    As an option the connector side of the cable may be protected with a flexible tube. There are 2 types:  

  • Protection cable-end (with or without pulling grip): This is made from a flexible tube and is meant as transport/pulling protection before and during installation and is completely removed after use. Outside this tube an optional cable pulling grip may be placed if the cable shall be pulled through tubes. 